Galvanized Steel EMT Conduit (EMT Conduit Pipe) – 1/2″ to 4″ with UL Listed for Electrical Wiring Protection – Supplier

$2.50

Product Description

Robustpro Structural EMT Conduit Pipe Made in China for Commercial

Product Description

Galvanized Steel EMT Conduit (EMT Conduit Pipe) - 1/2" to 4" with UL Listed for Electrical Wiring Protection - Supplier
EMT CONDUIT

Electrical metallic tubing (EMT), sometimes referred to as thin-wall conduit, is one type of tubing or conduit that is used to protect and route electrical wiring. Its lighter weight and lower cost make it more popular than galvanized rigid conduit (GRC), and it is most commonly used in commercial and industrial buildings.

UV TOLERANCE

EMT is generally coated with a protective layer to resist corrosion, but it is not designed for high UV resistance. Prolonged exposure to ultraviolet (UV) rays can lead to deterioration of the coating, which may affect the conduit’s protective properties. For installations exposed to direct sunlight or harsh outdoor conditions, using UV-resistant coatings or alternative conduit materials, such as PVC or specially treated metal conduits, may be necessary.

Galvanized Steel EMT Conduit (EMT Conduit Pipe) - 1/2" to 4" with UL Listed for Electrical Wiring Protection - Supplier

EMT conduit protects enclosed wires from damage caused by impact, moisture, and chemical fumes. Design and construction are simplified because multiple sizes and types of wires can be routed through a single conduit. This reduces the additional expense of multiple cable runs and custom composite cables. Wiring systems within buildings often need to be replaced, and EMT conduit makes this process easier and safer. Existing wires can be removed from the EMT conduit, and new wires can be installed without disrupting the entire installation process.

Galvanized Steel EMT Conduit (EMT Conduit Pipe) - 1/2" to 4" with UL Listed for Electrical Wiring Protection - Supplier
Galvanized Steel EMT Conduit (EMT Conduit Pipe) - 1/2" to 4" with UL Listed for Electrical Wiring Protection - Supplier
Galvanized Steel EMT Conduit (EMT Conduit Pipe) - 1/2" to 4" with UL Listed for Electrical Wiring Protection - Supplier

 

Product Parameters

TECHNICAL SPECIFICATIONS
Product Name EMT Conduit
Keywords Electrical Conduit
Parameter Customizable
Material Galvanized Steel
Surface Treatment Hot-dip Galvanized
Wall Thickness Range 1.4mm – 2.8mm
Elbow Types 90° Standard, 90° Long Radius, 45°, 30°, 22.5°
Bend Radius 4-6× Conduit Diameter
Temperature Range -20°C to +80°C
Crush Resistance ≥ 400N/5cm
Standards Compliance UL797, ANSI C80.3, NEMA FB-1, NFPA 70
Applications Structure Pipe
Installation Support Spacing Every 3m for Horizontal Runs
Corrosion Resistance Excellent for Indoor Environments
Electrical Continuity ≤ 0.1 Ω per joint
Galvanized Steel EMT Conduit (EMT Conduit Pipe) - 1/2" to 4" with UL Listed for Electrical Wiring Protection - Supplier
Galvanized Steel EMT Conduit (EMT Conduit Pipe) - 1/2" to 4" with UL Listed for Electrical Wiring Protection - Supplier

Detailed Photos

EXAMPLES OF USE

* Running electrical wiring in commercial and residential buildings.

* Protecting wiring in industrial facilities where physical damage is a concern.

* Using EMT conduit in renovation projects for easy installation and flexibility.

* EMT conduit is commonly used in indoor applications and dry locations.

* It is preferred for its ease of installation, lightweight nature, and the ability to be bent on-site.

Galvanized Steel EMT Conduit (EMT Conduit Pipe) - 1/2" to 4" with UL Listed for Electrical Wiring Protection - Supplier
MOST RESILIENT AND SUSTAINABLE

Long-lasting and highly recyclable, steel conduit and EMT demonstrate the greatest resiliency and are the most sustainable raceway options.

MOST FLEXIBLE AND AFFORDABLE

As buildings change and expand over time, other wiring solutions have to be removed and reinstalled – but steel conduit and EMT can be reused again and again. It might cost more upfront, but steel conduit and tubing deliver significant savings over time. The cost comparison in the following graphic shows the proof.

Galvanized Steel EMT Conduit (EMT Conduit Pipe) - 1/2" to 4" with UL Listed for Electrical Wiring Protection - Supplier
Galvanized Steel EMT Conduit (EMT Conduit Pipe) - 1/2" to 4" with UL Listed for Electrical Wiring Protection - Supplier
TEMPERATURE RANGE

EMT is typically designed to handle a temperature range from about -10°C to 60°C (14°F to 140°F), some within a temperature range of -30°C to 60°C (-22°F to 140°F). This can vary based on the raw materials used, so be sure to check with your supplier. This range covers most standard indoor and moderate outdoor conditions.

COMPRESSION RESISTANCE

EMT generally provides good resistance to compressive forces due to its steel construction, but it is not as robust as Rigid Metal Conduit (RMC) or Intermediate Metal Conduit (IMC). The standard for compression resistance is not explicitly defined for EMT in many codes, but it is expected to withstand normal mechanical stresses encountered during installation and use. For more rigorous compression requirements, RMC or IMC might be more appropriate.

Galvanized Steel EMT Conduit (EMT Conduit Pipe) - 1/2" to 4" with UL Listed for Electrical Wiring Protection - Supplier

 

Galvanized Steel EMT Conduit (EMT Conduit Pipe) - 1/2" to 4" with UL Listed for Electrical Wiring Protection - SupplierGalvanized Steel EMT Conduit (EMT Conduit Pipe) - 1/2" to 4" with UL Listed for Electrical Wiring Protection - SupplierGalvanized Steel EMT Conduit (EMT Conduit Pipe) - 1/2" to 4" with UL Listed for Electrical Wiring Protection - SupplierGalvanized Steel EMT Conduit (EMT Conduit Pipe) - 1/2" to 4" with UL Listed for Electrical Wiring Protection - SupplierGalvanized Steel EMT Conduit (EMT Conduit Pipe) - 1/2" to 4" with UL Listed for Electrical Wiring Protection - Supplier

FAQ

Q1: Are you a factory or a trading company?
A: We are a factory located in Dalian, Liaoning Province, China.

Q2: What’s the payment term?
A: We accept T/T 30% deposit and 70% before shipment, also Western Union, L/C At Sight is ok!

Q3: How to solve the problem of product error, leakage, and size?
A: We provide quality and quantity guarantees, and after-sales service can provide solutions quickly and online to ensure the interests and interests of customers.

Q4: Do you accept joint research and development of new products?
A: Of course, we can jointly develop new products based on samples or drawings provided by our customers. The details can be discussed in detail.

Q5: Are Regional product agents available?
A: We are happy to accept agency agreements, offer more favorable prices, and achieve long-term, friendly relationships.

Send your message to us